1. Lithium battery buck-boost test
First, let the lithium battery drop to 3.3V through the step-down chip, and then supply power to the microcontroller and the Bluetooth module, and plan to raise it to 7V to carry a load.
Result: The Bluetooth module does not work and cannot be searched. Remove the Bluetooth, the microcontroller and the load work normally. When the single-chip microcomputer is removed, the Bluetooth and the load work normally. When the voltage drop is not used, when a group of power is supplied separately, all three work normally.
Description: xc6206 for step-down and fd6291 for step-up.
2. Lithium battery step-up and step-down issues
Let's analyze the reasons for the above problems, find out the common faults of the lithium battery buck-boost, and learn together.
Lithium-ion batteries have a certain range of cell voltage. For example, the normal working voltage range of lithium iron phosphate batteries is 2.5V-3.65V, and the normal working voltage range of lithium manganese oxide and ternary batteries is 3V-4.2V.
In the application of lithium-ion batteries, when the total voltage is 60V and below, a battery protection board is required. Above 60V, a battery management system (BMS) is required. The role of these two devices is to protect the battery from working properly.
Note that after the number of strings of the battery pack is determined, the voltage of the battery pack cannot be adjusted arbitrarily. That is, the voltage change of the battery pack can only change within the normal working voltage range: when charging, it rises from the lower limit of the voltage to the upper limit of the voltage. When using electricity, it drops from the upper limit of the voltage to the lower limit of the voltage.
Understand this problem, if you want to make the lithium battery have a large range of buck-boost, you can adjust it at will.
The best solution: make a set of battery packs, equip a suitable inverter, and equip a DC voltage regulator to meet the voltage step-up and step-down requirements of lithium batteries.
Note: This method is rarely used in practical applications, unless the AC power used is often out of power, or when solar or wind energy is used to charge the battery pack, this method of step-up and step-down will be considered.
JUNLEE Group is an integrated full power energy factory that specializes in Uninterruptible Power Supply (UPS), Lead-Acid Battery, Battery pack, EV battery, Energy Storage Battery, Energy storage power station, Power pack Gel battery, PV Inverter and Solar system.
Production capacity reach 200000 KVaH per month. Products apply to Electric vehicles,electric mobility, solar & wind energy storage system, UPS, backup power, telecommunication, medical equipment and lighting.
JUNLEE sets up "Power research center" with more High-tech products.More than 100 engineers provided in-time and efficient one-stop solutions.
They mission strives to bring green power to the world.
To learn more about Li-ion batteries, please refer to https://www.junleepower.com/